Article source:
Applications
These flat parallel cables are designed for use on DCmining equipment, such as D.C. shuttle cars, drills, cutting and loading machines.
Standards
Construction
Options
Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.
Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.
Mechanical and Thermal Properties
Dimensions and Weight:
Construction | No. of Strands | Nominal Insulation Thickness | Nominal Overall Diameter Height×Width | Nominal Weight | Ampacity | |||
No. of cores×AWG/kcmil | inch | mm | inch | mm | lbs/kft | kg/km | A | |
2×8 | 133 | 0.06 | 1.5 | 0.51×0.84 | 13.0×21.3 | 340 | 506 | 72 |
2×6 | 133 | 0.06 | 1.5 | 0.56×0.93 | 14.2×23.6 | 440 | 655 | 95 |
2×4 | 259 | 0.06 | 1.5 | 0.61×1.05 | 15.5×26.7 | 550 | 818 | 127 |
2×3 | 259 | 0.06 | 1.5 | 0.68×1.14 | 17.3×29.0 | 675 | 1005 | 145 |
2×2 | 259 | 0.06 | 1.5 | 0.73×1.24 | 18.5×31.5 | 810 | 1205 | 167 |
2×1 | 259 | 0.08 | 2.0 | 0.81×1.40 | 20.6×35.6 | 1020 | 1520 | 191 |
2×1/0 | 259 | 0.08 | 2.0 | 0.93×1.51 | 23.6×38.2 | 1265 | 1880 | 217 |
2×2/0 | 329 | 0.08 | 2.0 | 0.99×1.63 | 25.1×41.4 | 1515 | 2255 | 250 |
2×3/0 | 413 | 0.08 | 2.0 | 1.03×1.77 | 26.2×45.0 | 1810 | 2694 | 286 |
2×4/0 | 532 | 0.08 | 2.0 | 1.10×1.89 | 27.9×48.0 | 2175 | 3237 | 328 |
Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.